0-65 Quick Menu Password
Range: Function:
200* [-9999 -
9999 ]
Define the password for access to the Quick
Menu via the [Quick Menu] key. If 0-66 Access
to Quick Menu w/o Password is set to Full
access [0], this parameter will be ignored.
0-66 Access to Quick Menu w/o Password
Option: Function:
[0] * Full access
Disables the password defined in 0-65 Quick
Menu Password.
[1] LCP: Read only Prevents unauthorised editing of Quick
Menu parameters.
[2] LCP: No access Prevents unauthorised viewing and editing
of Quick Menu parameters.
[3] Bus: Read only Read only functions for Quick Menu
parameters on fieldbus and/ or FC standard
bus.
[4] Bus: No access No access to Quick Menu parameters is
allowed via fieldbus and/ or FC standard bus.
[5] All: Read only read only function for Quick Menu
parameters on LCP, fieldbus or FC standard
bus.
[6] All: No access No access from LCP, fieldbus or FC standard
bus is allowed.
If 0-61 Access to Main Menu w/o Password is set to Full access
[0] then this parameter will be ignored.
0-67 Bus Password Access
Range: Function:
0* [0 - 9999 ] Writing to this parameter enables users to unlock
the frequency converter from bus/ MCT10.
How to Programme
VLT
®