16-71 Relay Output [bin]
Range: Function:
0 * [0 - 511 ] View the settings of all relays.
Illustration 3.65
16-72 Counter A
Range: Function:
0 * [-2147483648 -
2147483647 ]
View the present value of Counter A.
Counters are useful as comparator
operands, see 13-10 Comparator Operand.
The value can be reset or changed either
via digital inputs (parameter group 5-1*)
or by using an SLC action (13-52 SL
Controller Action).
16-73 Counter B
Range: Function:
0 * [-2147483648 -
2147483647 ]
View the present value of Counter B.
Counters are useful as comparator
operands (13-10 Comparator Operand).
The value can be reset or changed either
via digital inputs (parameter group 5-1*)
or by using an SLC action (13-52 SL
Controller Action).
16-74 Prec. Stop Counter
Range: Function:
0 * [0 - 2147483647 ] Returns the actual counter value of
precise counter (1-84 Precise Stop
Counter Value).
16-75 Analog In X30/11
Range: Function:
0.000 * [-20.000 - 20.000 ] View the actual value at input
X30/11 of MCB 101.
16-76 Analog In X30/12
Range: Function:
0.000 * [-20.000 - 20.000 ] View the actual value at input
X30/12 of MCB 101.
16-77 Analog Out X30/8 [mA]
Range: Function:
0.000 * [0.000 - 30.000 ] View the actual value at input X30/8
in mA.
16-78 Analog Out X45/1 [mA]
Range: Function:
0.000 * [0.000 - 30.000 ] View the actual value at output
X45/1. The value shown reflects the
selection in 6-70 Terminal X45/1
Output.
16-79 Analog Out X45/3 [mA]
Range: Function:
0.000 * [0.000 - 30.000 ] View the actual value at output
X45/3. The value shown reflects the
selection in 6-80 Terminal X45/3
Output.
3.17.5 16-8* Fieldbus & FC Port
Parameters for reporting the BUS references and control
words.
16-80 Fieldbus CTW 1
Range: Function:
0 * [0 - 65535 ] View the two-byte Control word (CTW)
received from the Bus-Master. Interpretation of
the Control word depends on the Fieldbus
option installed and the Control word profile
selected in 8-10 Control Profile.
For more information, refer to the relevant
Fieldbus manual.
16-82 Fieldbus REF 1
Range: Function:
0 * [-200 -
200 ]
View the two-byte word sent with the control
word form the Bus-Master to set the
reference value.
For more information, refer to the relevant
fieldbus manual.
16-84 Comm. Option STW
Range: Function:
0 * [0 - 65535 ] View the extended Fieldbus comm. option
status word.
For more information, refer to the relevant
Fieldbus manual.
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark 147
3