Enclosure Switching
pattern
High overload HO, 150% Normal overload NO, 110%
D1h–D8h
N55K to N315
525–690 V
60 AVM
130BX481.11
Iout [%]
fsw
[kHz]
70
80
90
1
60
100
110
2 3 4 54 50
6 7
50 ˚C (122 ˚F)
55 ˚C (131 ˚F)
130BX482.11
Iout [%]
fsw
[kHz]
70
80
90
1
60
100
110
2 3 54 50 6 7
50
45 ˚C (113 ˚F)
50 ˚C (122 ˚F)
55 ˚C (131 ˚F)
SFAVM
130BX483.11
Iout [%]
fsw
[kHz]
70
80
90
1
60
100
110
2 3 4 50
45 ˚C (113 ˚F)
50 ˚C (122 ˚F)
55 ˚C (131 ˚F)
130BX484.11
Iout [%]
fsw
[kHz]
70
80
90
1
60
100
110
2 3 4 50
50
40 ˚C (104 ˚F)
45 ˚C (113 ˚F)
50 ˚C (122 ˚F)
55 ˚C (131 ˚F)
E1h–E4h
N355 to N710
525–690 V
60 AVM
130BX489.11
Iout [%]
fsw
[kHz]
70
80
90
0.5
60
100
110
2.00.0 1.0 1.5 2.5 4.03.0 3.5
5.54.5 5.0
50 ˚C (122 ˚F)
55 ˚C (131 ˚F)
130BX490.11
Iout [%]
fsw
[kHz]
70
80
90
0.5
60
100
110
2.00.0 1.0 1.5 2.5 4.03.0 3.5 5.54.5 5.0
50
55 ˚C (131 ˚F)
45 ˚C (113 ˚F)
50 ˚C (122 ˚F)
SFAVM
130BX491.11
Iout [%]
fsw
[kHz]
70
80
90
0.5
60
100
110
2.00.0 1.0 1.5 2.5 4.03.0 3.5
55 ˚C (131 ˚F)
50 ˚C (122 ˚F)
45 ˚C (113 ˚F)
130BX492.11
70
80
90
0.5
Iout [%]
60
100
110
2.0
fsw
[kHz]
0.0 1.0 1.5 2.5 4.03.0 3.5
50
55 ˚C (131 ˚F)
50 ˚C (122 ˚F)
45 ˚C (113 ˚F)
40 ˚C (104 ˚F)
Table 9.5 Derating Tables for Drives Rated 525–690 V