VLT
®
AutomationDrive FC 302
N160 N200 N250 N315
High/normal overload HO NO HO NO HO NO HO NO
(High overload=150% current during 60 s,
normal overload=110% current during 60 s)
Typical Shaft output at 525 V [kW] 132 160 160 200 200 250 250 315
Typical Shaft output at 575 V [hp] 200 250 250 300 300 350 350 400
Typical Shaft output at 690 V [kW] 160 200 200 250 250 315 315 400
Enclosure size D2h/D4h/D7h/D8h
Output current (3-phase)
Continuous (at 525 V) [A] 201 253 253 303 303 360 360 418
Intermittent (60 s overload) (at 525 V)[A] 301 278 380 333 455 396 540 460
Continuous (at 575/690 V) [A] 192 242 242 290 290 344 344 400
Intermittent (60 s overload) (at 575/690 V) [A] 288 266 363 319 435 378 516 440
Continuous kVA (at 525 V) [kVA] 183 230 230 276 276 327 327 380
Continuous kVA (at 575 V) [kVA] 191 241 241 289 289 343 343 398
Continuous kVA (at 575/690 V) [kVA] 229 289 289 347 347 411 411 478
Maximum input current
Continuous (at 525 V) [A] 193 244 244 292 292 347 347 403
Continuous (at 575/690 V) 185 233 233 279 279 332 332 385
Maximum number and size of cables per phase
- Mains, motor, brake, and load share
[mm
2
(AWG)]
2x185 (2x350) 2x185 (2x350) 2x185 (2x350) 2x185 (2x350)
Maximum external mains fuses [A]
1)
550 550 550 550
Estimated power loss at 575 V [W]
2), 3)
2361 3074 3012 3723 3642 4465 4146 5028
Estimated power loss at 690 V [W]
2), 3)
2446 3175 3123 3851 3771 4614 4258 5155
Eciency
3)
0.98 0.98 0.98 0.98
Output frequency [Hz] 0–590 0–590 0–590 0–590
Heat sink overtemperature trip [°C (°F)]
110 (230) 110 (230) 110 (230) 110 (230)
Control card overtemperature trip [°C (°F)]
80 (176) 80 (176) 80 (176) 80 (176)
Table 7.6 Electrical Data for Enclosures D2h/D4h/D7h/D8h, Mains Supply 3x525–690 V AC
1) For fuse ratings, see chapter 10.5 Fuses and Circuit Breakers.
2) Typical power loss is at normal conditions and expected to be within
±
15% (tolerance relates to variety in voltage and cable conditions). These
values are based on a typical motor eciency (IE/IE3 border line). Lower eciency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-
eciency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for
slots A and B each add only 4 W.
3) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Eciency measured at nominal current. For energy
eciency class, see chapter 10.11 Eciency. For part load losses, see drives.danfoss.com/knowledge-center/energy-eciency-directive/#/.
Specications Design Guide
MG38C202 Danfoss A/S © 01/2018 All rights reserved. 41
7 7