15-07 Reset Running Hours Counter
Option: Function:
[0]
*
Do not reset Select
Do not reset
[0] if no reset of the Running Hours counter is desired.
[1] Reset counter Select
Reset counter
[1] and press [OK] to reset the Running Hours counter (par. 15-01) and
par. 15-08 Numbers
of Starts
, to zero (see also par. 15-01).
15-08 Numbers of Starts
Range: Function:
[0 - 2147483647] This is a read out parameter only. The counter shows the numbers of starts and stops caused by a normal Start/
Stop command and/or when entering/leaving sleep mode.
NB!
This parameter will be reset when resetting
par. 5-07 Reset Running Hours counter
.
3.15.3. Data Log Settings, 15-1*
The Data Log enables continuous logging of up to 4 data sources (par. 15-10) at individual rates (par. 15-11). A trigger event (par. 15-12) and window
(par. 15-14) are used to start and stop the logging conditionally.
15-10 Logging Source
Array [4]
None
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference %
[1603] Status Word
[1610] Power [kW]
[1611] Power [hp]
[1612] Motor Voltage
[1613] Frequency
[1614] Motor Current
[1616] Torque [Nm]
[1617] Speed [RPM]
[1618] Thermal Motor Load
[1622] Torque [%]
[1630] DC Link Voltage
[1632] Brake Energy / s
[1633] Brake Energy / 2 min
[1634] Heatsink Temp.
[1635] Thermal Drive Load
[1650] External Reference
[1652] Feedback [Unit]
[1654] Feedback 1 [Unit]
[1655] Feedback 2 [Unit]
[1656] Feedback 3 [Unit]