Application guidelines
49FRCC.PC.023.A7.22
Single compressorsSystem design recommendations
Compressor VZH088 VZH117 VZH170
“OS separator
(CE)”
Brand Chiyoda
Contact information
Email: sales@chiyodaseiki.com
Tel: +86(512)62833498
Address: No.1 Sheng gang Rd, Suzhou Industrial Park, Jiang su,PRC, China.
Website: http://www.chiyodaseiki.com/
Model OS-165DF088CE OS-165DF117CE OS-165DF170CE
outline
Type centrifugal
ФD: Outter Diameter(mm) Φ165.2 Φ165.2 Φ165.2
Volume(L) 7.2 8.3 10.5
Inlet size(in) 7/8'' 7/8'' 1''1/8
outlet size (in) 7/8'' 7/8'' 1''1/8
Footprint LxW(mm x mm) 190.5x102
H1: Height(mm) 297 355 469
H2: Height(mm) 457 515 635
H: Height(mm) 469 527 645
Capillary tube
Inner diameter(mm) Φ1.6 Φ1.8 Φ1.8
length(mm) 1400 1530 1380
Strainer Mesh size 100 100 100
Solenoiid valve
“Model: Danfoss
(Orice Φ2.0)
(CE)”
Orice(mm) Φ2.0
code number 032F1201
connection(in) 1/4''
solenoil coil
“24V
50Hz AC”
code number 018F6257
specication 1m 3-core cable
“220-230V
50/60Hz AC”
code number 018F6282
specication 1m 3-core cable