CE870 Instant Issuance System Installation and Administrator’s Guide 93
 MS2CustomCharLow1—Specify the numeric value of the lowest ASCII character supported
for input data on the track.
 MS2CustomCharMask1—Specify the mask value that is subtracted from the ASCII numeric
value to get the encoded value.
 MS2CustomCharMax1—Specify the maximum number of data characters for the track. The
value does not include the Start or End Sentinels.
 MS2CustomDensity1—Specify the number of data bits per inch of magnetic stripe media for
the track, also called bits per inch or bpi. Allowed values are 75 bpi or 210 bpi.
 MS2CustomEndSentinel1—Specify the last character encoded, which identifies the end of
encoded data for the track.
 MS2CustomLrc1—Specify a cumulative parity bit that is encoded after the end sentinel to
provide simple error checking.
 MS2CustomParity1—Specify a character-level parity bit encoded after each character to
provide simple error checking.
 MS2CustomSdsNulls1—The number of nulls between each copy of the data record. You
should not change this value.
 MS2CustomSdsRecords1—The number of times to encode the data record. You should not
change this value.
 MS2CustomSdsSs1—The number of start sentinels before each data record. You should not
change this value.
 MS2CustomStartSentinel1—Specify the first character encoded, which identifies the start of
the encoded data for the track.
Using a custom magnetic stripe data format is a two-step process. First, define the custom track
using MagStripeMS2CustomTrack1. Second, apply the custom track using the settings on the
MagStripeMS2General menu.
1. To use the defined custom track:
a. Open the MagStripeMS2General menu.
b. Select CUSTOM for MS2DataFormat1 to use the custom track.
2. Click Set Current to apply the changes.

Table of Contents

Other manuals for DataCard CE840

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DataCard CE840 and is the answer not in the manual?

DataCard CE840 Specifications

General IconGeneral
BrandDataCard
ModelCE840
CategoryPrinter
LanguageEnglish

Related product manuals