DM984 product family CHAPTER 10. FIRST STEPS WITH IPSAN
DM4650(unit-gpon-7)#show this
Unit: 7
Authentication method: serial-number
Key exchange interval: 3600
DM4650(unit-gpon-7)#
To exit a menu this command is given:
exit
Example:
DM4650(config)#exit
DM4650#
10.3 Saving configurations
There are two options for saving configurations to the persistent flash storage
of the IPSAN. The first option is in combination with marking it as startup-
configuration and the second option is without marking it as startup configu-
ration. When a configuration is marked as startup-configuration it gets loaded
upon the next startup of the IPSAN.
To save a configuration and mark it for the next startup the following command
must be issued:
copy running-config startup-config <flash-position>
Description of the used parameters:
Name Format Description
<flash-position> Number (1-10) Position where the configuration is stored
Example:
DM4650#copy running-config startup-config 10
Saving running configuration in flash 10...
DM4650#
To store a configuration without marking it as startup the following command is
given at the standard prompt:
copy running-config flash-config <flash-position>