Maintenance LED (Red LED) - Continued
Blink red, 3 quick pulses
FOD (Foreign Object Detection). It’s a WLC
error related to metallic parts between
transmitter and receiver coils. The power
transfer is suspended. Solution: remove
the device from the cradle, then remove the
metallic part causing the problem.
Blink red, 4 quick pulses
EOC (end of charge) timeout error. The WLC
EOC signal has been kept enabled by the
terminal for too much time. Typically, it is
caused by a bug in the terminal firmware.
The power transfer is disabled.
Blink red, 5 quick pulses
WLC generic error. The WLC system seems
unstable and unable to setup a stable
power transfer within a reasonable time.
The power transfer is suspended. Solution:
try to extract the device from the cradle
and to re-insert it again.
Blink red, 6 quick pulses Device charging error.
Solid red Firmware upgrade.
NOTE
For further information on the Joya Touch Single Slot Dock
Locking, refer to the Single Slot Dock Locking Quick Start
Guide, included in the dock’s box.