EasyManua.ls Logo

Datalogic MAGELLAN 8200

Datalogic MAGELLAN 8200
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Reference Guide 4-7
Other Scale Reporting
- 0 - Off
Cannot zero at power- up or
weight remains on scale for
more than 4 minutes or
weight has not returned to
zero between POS weight
requests
a
.
- Check debris chutes.
- Verify that the weigh platter moves
freely.
- Remove item(s) from scale
- Press Scale Zero Push Button for
more information.
- If the scale still fails to zero, recali-
brate the scale.
__--- Off
Over- and underweight con-
ditions.
- Remove all weight from scale
- Rezero.
a.This is a configurable feature.
Table 4-2. Scale Error Reporting
Remote
Display
Scale Status
Lamp
Problem
Description
Action Required

Table of Contents

Related product manuals