HOST MODE PROGRAMMING
8
3
At Least One (Type = 4)
Item List
List of the allowed values of the parameter
Selection
Maximum number of values selectable at the same time (normally the number of items
available in the list).
Default
Default entries (2
0
= first entry of the list, 2
1
= second entry of the list, .2
2
= third entry of the
list). The default value is given by the sum of the selected entries of the list.
Example
: Reading Phase ON parameter
Type: 4
Label: Reading Phase ON
Item List
External Trigger Leading Edge, External Trigger Trailing Edge, Main Port
String, Auxiliary Port String, Input 2 Leading Edge, Input 2 Trailing Edge,
Ethernet String, Fieldbus String, Fieldbus Input Leading Edge, Fieldbus Input
Trailing Edge
Selection: 9
Default: 1 (2
0
External Trigger Leading Edge)
Caution: This parameter type cannot be set to 0.
Example
:
External Trigger Leading Edge: Entry 0 Value = 2
0
= 1.
External Trigger Trailing Edge: Entry 1 Value = 2
1
= 2.
Main Port String + Auxiliary Port String: Entry 2 + Entry 3 Value = 2
2
+ 2
3
= 12.

Other manuals for Datalogic Matrix 210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Matrix 210 and is the answer not in the manual?

Datalogic Matrix 210 Specifications

General IconGeneral
BrandDatalogic
ModelMatrix 210
CategoryBarcode Reader
LanguageEnglish

Related product manuals