HOST MODE PROGRAMMING
28
4
PARAMETER TYPE SEL STRING DATA
SIEMENS PROTOCOL
Protocol Checksum 1 1 ESC C A 0 = Disabled
1 = Enabled
Protocol Priority 1 1 ESC C B 0 = Low
1 = High
Header Character 5 2 ESC C D Length: 0 to 1
Header Character 6 2 ESC C E Length: 0 to 1
Header Character 9 2 ESC C G Length: 0 to 1
Header Character 10 2 ESC C G Length: 0 to 1
Fill Character 1 ESC C H Length: 0 to 1
Fill Position 1 1 ESC C I 0 = Before Data
1 = After Data
AUXILIARY PORT
Communication Mode 1 1 ESC D A 0 = Standard
1 = Local Echo
2 = Pass-Through
Search For CBX At
Device Startup
1 1 ESC D L 0 = Disabled
1 = Enabled
Baud Rate 1 1 ESC D B 0 = 2400
1 = 4800
2 = 9600
3 = 19200
4 = 38400
5 = 57600
6 = 115200
Parity 1 1 ESC D C 0 = None
1 = Odd
2 = Even
Data Bits 1 1 ESC D D 0 = 7
1 = 8
Stop Bits 1 1 ESC D E 0 = 1
1 = 2
Communication
Handshake
1 1 ESC D F 0 = None
1 = XON/XOFF
2 = RTS/CTS
Header String 2 ESC D G Length: 0 to 128
Terminator String 2 ESC D H Length: 0 to 128
Reading Phase ON
String
2 ESC D I Length: 0 to 128
Acquisition Trigger
String
2 ESC D J Length: 0 to 128
Reading Phase OFF
String
2 ESC D K Length: 0 to 128

Other manuals for Datalogic Matrix 210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Matrix 210 and is the answer not in the manual?

Datalogic Matrix 210 Specifications

General IconGeneral
BrandDatalogic
ModelMatrix 210
CategoryBarcode Reader
LanguageEnglish

Related product manuals