EasyManuals Logo

DCS 9 Series User Guide

DCS 9 Series
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10
Gas Requirements
z
Do not change the regulator/hose assembly from that supplied with the unit or attempt
to use a Type 1 equipped regulator/hose assembly with a standard 510 POL cylinder/
valve assembly.
z
The cylinder pressure relief valve outlet must point away from the user when in use.
z
An installer-supplied gas shut-off valve must be installed in an easily accessible location.
z
All installer supplied parts must conform to local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical
Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CSA-B149.1 Natural
Gas Installation Code or CSA-B149.2 Propane Installation Code.
z
In Massachusetts such shut-off valves should be approved by the Board of State
Examiners or Plumbers & Gas Fitters.
z
All pipe sealants must be an approved type and resistant to the actions of LP gases.
Never use pipe sealant on flare fittings.
z
A dented or rusty LP cylinder may be hazardous and should be checked by your
LP supplier.
z
Always check for leaks after every LP cylinder change. Check with a full cylinder.
z
Do not use the appliance until all connections have been checked and do not leak.
z
Before each use, inspect the gas supply piping or hose prior to turning the gas ON. If
there is evidence of cuts, wear, or abrasion, it must be replaced prior to use.
z
The pressure regulator and hose assembly supplied with the appliance must be used. If
replacements are needed, contact Customer Care.
Storage and maintenance
z
Ensure the gas supply is turned off at the supply cylinder when not in use.
z
Keep appliance covered when not in use.
z
Storage of the appliance indoors is permissible only if the cylinder is disconnected and
removed from the unit.
z
Cylinders must be stored outdoors, out of reach of children and must not be stored in a
building, garage, or any other enclosed area.
z
After a period of storage or non-use, the appliance should be checked for gas leaks,
deterioration, proper assembly, and burner obstructions before use.
z
Keep the outdoor gas appliance area clear and free from combustible materials,
gasoline, and other flammable vapours and liquids.
z
Clean the outdoor gas appliance, including special surfaces with recommended
cleaning agents and check burner/venturi tubes for insects and insect nests. A clogged
tube can lead to a fire beneath the grill.
LP Cylinder Cabinet Requirements
For a cylinder enclosure having four sides, a top and a bottom, and intended for
installation in a built-in enclosure:
z
At least one ventilation opening shall be provided on the exposed exterior side of the
enclosure located within 5" (127mm) of the top of the enclosure and unobstructed. The
opening(s) shall have a total free area of not less than 1"²/lb (14.2cm²/kg) of stored
fuel capacity.
z
At least one ventilation opening shall be provided on the exposed exterior side of the
enclosure 1" (25.4mm) or less from the floor level and shall have a total free area of not
less than 1/2"²/lb (7.1cm²/kg) of stored fuel capacity. The upper edge shall be no more
than 5" (127mm) above the floor level.
z
Every opening shall have a minimum dimension so as to permit the entrance of a 3/16"
(4.8mm) rod.
SAFETY AND WARNINGS

Other manuals for DCS 9 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DCS 9 Series and is the answer not in the manual?

DCS 9 Series Specifications

General IconGeneral
BrandDCS
Model9 Series
CategoryGrill
LanguageEnglish

Related product manuals