Section 2 Installation
Overshelf Installation
65. Install the tubular legs of the overshelf over the
bushings. A #8 x 0.37” sheet metal Phillips head screw
serves as a set screw to hold the overshelf legs securely
against the bushing.
66. If two overshelves are mounted adjacent to each other,
they will have a spline joint similar to those found on
base units. Use #8 x 0.75” pan Phillips head screw with
1/4-20 locking nut to secure the overshelves.
67. Overshelves with heat lamps or other electrical
accessories will have a two-piece channel provided at
one end for an electrical raceway. The cover can be
removed to allow wiring of accessory items.
68. Ensure that all hardware is tightened securely.
Power Supply Re-Assembly
69. Electrical requirements vary. Check the ratings listed on
the serial tag for requirements.