User’sGuide
deliberant Page48
Systemalerts
The device is able to send external alerts when there are system errors. The alerts can be sent via
SNMP Traps or/and SMTP notifications.
Figure 48 – Device Alerts
Enable alerts – select to enable alert notifications on the system.
System check interval, s – specify interval in seconds at which the device will send notifications of
unexpected system behavior.
System alerts:
Wireless link status change – system will send notification on Wireless link status change.
Ethernet link status change – system will send notification on Ethernet link status change.
RSSI level lower than – system will send notification when RSSI reach value lower than specified.
Default: 25
Noise level greater than – system will send notification when signal noise will reach value greater
than specified. Default: -60 dBm.
RX drop greater than – system will send notification when percent of RX dropped packets become
higher than specified value. Default: 250 packets per seconds.
TX retry greater than – system will send notification when percent of TX retries becomes higher than
specified value. Default: 250 packets per seconds.
Device reboot – system will send notification about unexpected or administrator initiated device
reboot.
Figure 49 – Device Alerts: SNMP Traps and SMTP Configuration