Expanded operating temperature
Table 37. Expanded operating temperature specifications
Expanded operating temperature Specifications
Continuous operation 5°C–40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C–
35°C), the system can operate continuously in temperatures as
low as 5°C and as high as 40°C.
For temperatures between 35°C–40°C, de-rate maximum allowable
temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
≤ 1% of annual operating hours –5°C–45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C–
35°C), the system can operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable
temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD
panel and in the System Event Log.
Expanded operating temperature restrictions
Do not perform a cold startup below 5°C.
The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
150 W/8 C, 165 W/12 C and higher wattage processor(TDP>165 W) are not supported.
Redundant power supply unit is required.
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
NVDIMM-Ns are not supported.
DCPMMs are not supported.
GPU is not supported.
PCIe SSD is not supported.
Rear installed drives are not supported
Tape backup unit is not supported.
Thermal restrictions
The following table lists the configurations required for efficient cooling.
Table 38. Thermal restrictions configuration
Configuration
Number
of
process
ors
Heatsink
Processor/
DIMM blank
DIMM
blanks
Maximum number of
DIMM blanks
Fan
PowerEdge
R640 (2.5 inch
hard drives x
10)
1
One 1U standard heat
sink for CPU ≤ 165 W
Not required
Required for
processor 1
11 blanks
Five standard fans
One 1U 2-pipe heat
sink for CPU=200/205
W and 150 W/165 W
FO*
Required
Eight high performance
fans
2
Two 1U standard heat
sink for CPU ≤ 165 W
Not required
Eight standard fans
Two 1U 2-pipe heat
sink for CPU=200/205
Required 22 blanks
Eight high performance
fans
52 Technical specifications