3. Using the "17th blade" feature of the CMC, use the Connect Switch-X command to verify that the switch is fully
booted, and verify the switch’s firmware revision and IP address.
4. Verify that the switch module has a valid IP address for the subnet. Verify using the ICMP ping command.
5. Check the network connector indicators on the network switch module:
If the link indicator displays an error condition, check all cable connections.
Try another connector on the external switch or hub.
If the activity indicator does not light, replace the network switch module.
6. Using the switch management interface, verify the switch port properties. If the switch is configured correctly,
back up the switch configuration and replace the switch. See the switch module documentation for details.
7. If the blade requires a mezzanine card for a particular network switch module, ensure that the appropriate
mezzanine card is installed. If so, reseat the mezzanine card. If the network link indicator on the blade is green,
then the blade has a valid link to the appropriate network switch module.
8. Ensure that the appropriate operating system drivers are installed and that the protocol settings are configured to
ensure proper communication.
96

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell External M1000e t and is the answer not in the manual?

Dell External M1000e t Specifications

General IconGeneral
Rack Units10U
ModelM1000e
Power SupplyUp to 6 power supply units (PSUs)
Form FactorEnclosure
CoolingRedundant, hot-swappable fans
ManagementDell Chassis Management Controller (CMC)
CompatibilityDell PowerEdge blade servers
NetworkingFibre Channel, InfiniBand

Related product manuals