30 Installing the Hardware
E600i TeraScale Environmental Parameters
E600i TeraScale AC Power Supply Unit Requirements
Width 17.4 inches (44.2 cm)
Depth (without cable management
system)
21.5 inches (54.6 cm)
Chassis weight with factory-installed
components (backplane and air filter)
81 pounds (36.7 kg)
Weight fully loaded (backplane, air
filter, fan tray, SFMs, RPMs, and 7 line
cards)
242 pounds (109.8 kg)
Maximum Thermal Output
NOTE: Thermal output is directly proportional to system configuration and
number of line cards.
Maximum for fully loaded chassis 120 VAC powered: 4705W (16,065
BTU/hour)
200/240 VAC powered: 4250W (14,500
BTU/hour)
DC powered: 2800W (9600 BTU/hour)
Parameter Specifications
Operating
Temperature 32° to 104°F (0° to 40°C)
Maximum altitude No performance degradation to 10,000 feet (3,048 meters)
Relative humidity 5 to 85 percent, non-condensing
Non-operating
Temperature -40° to 158°F (-40° to 70°C)
Maximum Altitude 15,000 feet (4,572 meters)
Relative Humidity 5 to 95 percent, non-condensing
Parameter Specifications
Nominal input voltage 120 - 240 VAC 50/60 Hz