Installing the Hardware 35
E1200i ExaScale Environmental Parameters
E1200i ExaScale Power Requirements
Weight fully loaded
(backplane, air filter, 2 fan
trays, 10 SFM3s, RPMs, and
14 line cards)
422 pounds (approx.)
(191.2 kg)
319 pounds (approx.)
(144.70 kg)
Thermal Output
Maximum (fully-loaded
chassis with 10-port 10GE
line cards)
18,368 BTU/hr 16,446 BTU/hr
Minimum (chassis with one
10-port 10GE line card)
2,313 BTU/hr 1,997 BTU/hr
Parameter Specifications
Operating
Temperature 32° to 104°F (0° to 40°C)
Maximum altitude No performance degradation to 10,000 feet (3,048 meters)
Relative humidity 5 to 85 percent, non-condensing
Shock Designed to meet Telcordia GR-63 CORE
Vibration Designed to meet Telcordia GR-63 CORE
Non-operating
Temperature -40° to 158°F (-40° to 70°C)
Maximum Altitude 15,000 feet (4,572 meters)
Relative Humidity 5 to 95 percent, non-condensing
Vibration Bellcore GR-63
Parameter E1200i AC Specifications E1200i DC Specifications
Nominal input voltage 200-240 VAC 50/60 Hz -44 to 60 VDC
Maximum Power
Consumption
6,634 W 5,400 W
Parameter E1200i AC Specifications E1200i DC Specifications