34 Installing the Hardware
E1200i TeraScale Power Requirements
E1200i ExaScale Chassis Physical Design
Vibration Designed to meet Telcordia GR-63 CORE
Non-operating
Temperature -40° to 158°F (-40° to 70°C)
Maximum Altitude 15,000 feet (4,572 meters)
Relative Humidity 5 to 95 percent, non-condensing
Vibration Bellcore GR-63
Parameter E1200i AC Specifications E1200i DC Specifications
Nominal input voltage 200-240 VAC 50/60 Hz -44 to 60 VDC
Maximum Power
Consumption
5,734 @ 200/240 VAC 5,210 W
Maximum Thermal
Output
18,710 BTU/hour (5,484 W) 16,924 BTU/hour (4,910 W)
Maximum Input
Current
(per power supply)
15.0 A @ 200 VAC
12.5 A @ 240 VAC
(per DC PEM)
150 A
Maximum System
Power Input
5.8 KVA @ 200/240 VAC
Parameter E1200i AC Specifications E1200i DC Specifications
Height 42 inches (106.68 cm) 36.75 inches (93.35 cm)
Width 17.40 inches (44.20 cm) 17.40 inches (44.20 cm)
Depth (without cable
management system)
22.25 inches (56.51 cm) 21.25 inches (53.98 cm)
Chassis weight with factory-
installed components
(backplane and air filter)
139 pounds (approx.)
(63.05kg)
97 pounds (approx.) (44.00
kg)
Parameter Specifications