168 Managing a Switch Stack
At this point, if Unit 2 is powered off or rebooted due to an unexpected
failure, show switch gives the following output:
console#show switch
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the stack master.
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member PC8024 PC8024 OK 9.19.0.2
2 Unassigned PC8024 Not Present 0.0.0.0
3 Mgmt Switch PC8024 PC8024 OK 9.19.0.2
4 Stack Member PC8024F PC8024F OK 9.19.0.2
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member PC8024 PC8024 OK 9.19.0.2
3 Mgmt Switch PC8024 PC8024 OK 9.19.0.2
4 Stack Member PC8024F PC8024F OK 9.19.0.2