EasyManua.ls Logo

Dell PowerConnect 8132 - Page 410

Dell PowerConnect 8132
1294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
410 Configuring iSCSI Optimization
The following commands show how to configure the iSCSI example depicted
in Figure 17-6. Remember that iSCSI optimization is enabled by default.
1
Set the MTU to 9216 to enable the use of jumbo frames.
console#config
console(config)#ip mtu 9216
2
Optionally configure the switch to associate CoS queue 5 with detected
iSCSI session traffic.
console(config)#iscsi cos enable
console(config)#exit
The default target port and IP address criteria is used to determine which
packets are snooped for iSCSI session data (ports 860 and 3260; any IP
address).
3
If the array is a Compellent storage array, execute the Compellent macro
on the ports attached to the array:
console#config
console(config)#macro global apply profile-compellent-nas
$interface_name te1/0/21
console(config)#macro global apply profile-compellent-nas
$interface_name te1/0/22
console(config)#macro global apply profile-compellent-nas
$interface_name te1/0/23
To configure a PC81xx switch in a lossless DCBX environment where another
switch connected to storage arrays supplies the DCBX configuration, perform
the following steps starting with a default configuration:
1
Enter global configuration mode and configure the MTU on the switch.
console#configure
console(config)#ip mtu 9216
2
Create VLAN 100. This command also enters the VLAN configuration
mode for VLAN 100.
console(config)#vlan 100
console(config-vlan100)#exit
3
Enable VLAN tagging to allow the CNA ports 1-4 to carry 802.1p priority
values through the network.
console(config)#interface range te1/0/1-4
console(config-if)#switchport mode trunk

Table of Contents

Other manuals for Dell PowerConnect 8132