EasyManua.ls Logo

Dell PowerEdge R860 - Page 110

Dell PowerEdge R860
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 86. 16 x 2.5-inch (SAS4/SATA) with fPERC 11
Order From To
1 CTRL_SRC_SB1 (fPERC controller connector) BP_DST_SA1 (backplane signal connector)
2 SL4_CPU1_PA3 (signal connector on system
board)
CTRL_DST_PA1 (fPERC controller
connector)
3 SIG_PWR_2 (system board power connector) BP_PWR_1 (backplane power connector)
4 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
Figure 71. Configuration 19: 16 x 2.5-inch (SAS4/SATA) with fPERC 12
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 87. 16 x 2.5-inch (SAS4/SATA) with fPERC 12
Order From To
1 CTRL_SRC_SB1_PB1 (fPERC controller connector) BP_DST_SA1 (backplane signal connector)
2 SL4_CPU1_PA3 (signal connector on system
board)
CTRL_DST_PA1 (fPERC controller
connector)
3 SL5_CPU1_PB3 (signal connector on system
board)
CTRL_DST_PB1 (fPERC controller
connector)
4 SIG_PWR_2 (system board power connector) BP_PWR_1 (backplane power connector)
5 SIG_PWR_1 (system board power connector) BP _PWR_1 (backplane power connector)
6 CTRL_SRC_SA1_PA1 (fPERC controller connector) BP_DST_SA1 (backplane signal connector)
110 Installing and removing system components

Table of Contents

Related product manuals