Table 50. HTTP Device n Settings details (continued)
Option Description
URI Obtain URI from the DHCP server if not specified
TLS Authentication
Configuration
Specifies the option for TLS authentication configuration.
Table 51. ISCSI Device1 Settings screen details
Option Description
Connection 1 Enables or disables the ISCSI connection. This option is set to Disabled by default.
Connection 2 Enables or disables the ISCSI connection. This option is set to Disabled by default.
Connection 1 Settings Enables you to control the configuration for the ISCSI connection.
Connection 2 Settings Enables you to control the configuration for the ISCSI connection.
Connection Order Enables you to control the order for which the ISCSI connections will be
attempted.
Table 52. TLS Authentication Configuration screen details
Option Description
TLS Authentication Mode View or modify the device's boot TLS Authentication Mode. This option is set to One
Way by default. None means the HTTP server and the client will not authenticate each
other for this boot.
Root Certificate Configuration Import, delete, or export the root certificate.
Table 53. NVMe-oF SubSystem Settings screen details
Option Description
NVMe-oF SubSystem n (n = 1 to 4) Enables or disables NVMe-oF SubSystem. This option is set to Disabled by
default.
NVMe-oF SubSystem n Settings (n = 1
to 4)
Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.
Table 54. NVMe-oF SubSystem n Settings
Option Description
Interface NIC interface used for NVMe-oF connections. This option is set to Embedded
NIC 1 Port 1 Partition 1 by default.
Transport Type This field sets the value of transport type for NVMe-oF connection. This option is
set to TCP by default.
Protocol This field sets the value of protocol type for NVMe-oF connection. This option is
set to IPv4 by default.
VLAN Enables or disables VLAN for this NVMe-oF connections. This option is set to
Disabled by default.
VLAN Id Specifies the VLAN Id for this NVMe-oF connection. This option is set to 1 by
default.
VLAN Priority Specifies the VLAN priority for this NVMe-oF connection. This option is set to 0 by
default.
Retry Count Specifies the retry count for this NVMe-oF connection. This option is set to 3 by
default.
Timeout Specifies the timeout for this NVMe-oF connection. This option is set to 10000 by
default.
Pre-operating system management applications 53

Table of Contents