EasyManua.ls Logo

Dell PowerEdge R860 - Page 97

Dell PowerEdge R860
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 57. Configuration 5: 24 x 2.5-inch (SAS4/SATA) with fPERC 12
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 73. 24 x 2.5-inch (SAS4/SATA) with fPERC 12
Order From To
1 SL4_CPU1_PA3 (signal connector on system board) CTRL_DST_PA1 (fPERC controller connector)
2 CTRL_SRC_SB1_PB1 (fPERC controller connector) BP_DST_SB1 (backplane signal connector)
3 SL5_CPU1_PB3 (signal connector on system board) CTRL_DST_PB1 (fPERC controller connector)
4 SIG_PWR_2 (system board power connector) BP_PWR_2 (backplane power connector)
5 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
6 CTRL_SRC_SA1_PA1 (fPERC controller connector) EXP/BP_DST_SA1 (backplane signal connector)
Installing and removing system components 97

Table of Contents

Related product manuals