EasyManua.ls Logo

Dell PowerEdge R860 - Page 99

Dell PowerEdge R860
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 59. Configuration 7: 24 x 2.5-inch (SAS4/SATA) + 2 x 2.5-inch (SAS/SATA) with fPERC 12
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 75. 24 x 2.5-inch (SAS4/SATA) + 2 x 2.5-inch (SAS/SATA) with fPERC 12
Order From To
1 CTRL_SRC_SB1_PB1 (fPERC controller
connector)
BP_DST_SB1 (backplane signal connector)
2 SL4_CPU1_PA3 (signal connector on system
board)
CTRL_DST_PA1 (fPERC controller connector)
3 SL4_CPU1_PA3 (signal connector on system
board)
BP_DST_SA1 and BP_DST_SB1 (backplane signal
connector)
4 SIG_PWR_2 (system board power connector) BP_PWR_2 (backplane power connector)
5 SIG_PWR_1 (system board power connector) BP _PWR_1 (backplane power connector)
6 SL5_CPU1_PB3 (signal connector on system
board)
CTRL_DST_PB1 (fPERC controller connector)
7 CTRL_SRC_SA1_PA1 (fPERC controller
connector)
EXP/BP_DST_SA1 (backplane signal connector)
8 SIG_PWR_0/BATT2 (system board power
connector)
BP _PWR_1 (Rear backplane signal connector)
Installing and removing system components 99