Figure 60. Configuration 8: 24 x 2.5-inch (SAS4/SATA) - Dual controller (fPERC 12)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 76. 24 x 2.5-inch (SAS4/SATA) - Dual controller (fPERC 12)
Order From To
1 SL4_CPU1_PA3 (signal connector on system
board)
CTRL_DST_PA1 (fPERC controller connector)
2 CTRL_SRC_SA1 (Adapter PERC controller
connector)
BP_DST_SB1 (backplane signal connector)
3 SIG_PWR_2 (system board power connector) BP_PWR_2 (backplane power connector)
4 SIG_PWR_1 (system board power connector) BP _PWR_1 (backplane power connector)
5 CTRL_SRC_SA1_PA (fPERC controller
connector)
EXP/BP_DST_SA1 (backplane signal connector)
6 SL5_CPU1_PB3 (signal connector on system
board)
CTRL_DST_PB1 (fPERC controller connector)