Video specifications
Video Specification
Video type Integrated Matrox G200
Video memory 16 MB shared
Expanded operating temperature
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be
reported on the LCD and in the System Event Log.
Expanded
operating
temperature
Specifications
≤ 10% of annual
operating hours
5°C to 40°C at 5% to 85% RH with 26°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the system
can operate down to 5°C or up to 40°C for a maximum of 10% of its annual
operating hours.
For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb
temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
≤ 1% of annual
operating hours
–5°C to 45°C at 5% to 90% RH with 26°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the system
can operate down to –5°C or up to 45°C for a maximum of 1% of its annual
operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable dry bulb
temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
Expanded
Operating
Temperature
Restrictions
The operating temperature specified is for a maximum altitude of 3048 m
(10,000 ft).
Non-redundant power supply units are not supported.
Cabled power supply units are not supported.
Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W
are not supported.
Internal Tape backup drive (TBU) is not supported.
Do not perform a cold startup below 5°C.
Enable processor performance degrade.