Dell poweredge t330 - Indicator Codes for Non-Redundant Power Supply Unit

Dell poweredge t330
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Convention Power Indicator
Pattern
Description
CAUTION: When correcting a PSU mismatch, replace only the
PSU with the flashing indicator. Swapping the other PSU to
make a matched pair can result in an error condition and
unexpected system shutdown. To change from a High Output
configuration to a Low Output configuration or vice versa,
you must power down the system.
CAUTION: AC PSUs support both 220 V and 110 V input
voltages with the exception of Titanium PSUs, which support
only 220 V. When two identical PSUs receive different input
voltages, they can output different wattages, and trigger a
mismatch.
CAUTION: If two PSUs are used, they must be of the same type
and have the same maximum output power.
CAUTION: Combining AC and DC PSUs is not supported and
triggers a mismatch.
E Not lit Power is not connected.
Indicator codes for non-redundant power supply unit
Press the self-diagnostic button to perform a quick health check on the non-redundant power supply
unit (PSU) of the system.
Figure 9. Non-redundant AC PSU status indicator and self-diagnostic button
1. self-diagnostic button 2. AC PSU status indicator
Table 10. Indicator codes for non-redundant power supply unit
Diagnostic Indicator Pattern Description
Not lit Power is not connected or PSU is faulty.
Green A valid power source is connected to the PSU and the PSU is
operational.
26