Figure 31. Installing the memory module
1. memory module 2. alignment key
3. memory module socket ejector (2)
Next steps
1. Follow the procedure listed in the After working inside your system section.
2. Press F2 to enter System Setup, and check the System Memory setting.
The system should have already changed the value to reflect the installed memory.
3. If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure
that the memory module is firmly seated in the memory module socket.
4. Run the system memory test in system diagnostics.
Related Links
Safety instructions
Before working inside your system
After working inside your system
Removing memory modules
Removing the optional cooling fan assembly
Flex bays
Your system's flex bay supports sixteen 2.5 inch hard drives or four Dell PowerEdge Express Flash devices.
Removing a flex bay
Prerequisites
1. Follow the safety guidelines listed in the safety instructions section.