Figure 8. DC PSU status indicator
1. DC PSU status indicator
Table 8. DC PSU status indicators
Convention Power indicator
pattern
Condition
A Green A valid power source is connected to the PSU and that the PSU is
operational.
B Flashing green When hot-adding a PSU, the PSU indicator flashes green. This
indicates that there is a PSU mismatch with respect to efficiency,
feature set, health status, and supported voltage. Ensure that both
the PSUs are of the same capacity.
C Flashing amber Indicates a problem with the PSU.
CAUTION: When correcting a PSU mismatch, replace only
the PSU with the flashing indicator. Swapping the PSU to
make a matched pair can result in an error condition and
unexpected system shutdown. To change from a High
Output configuration to a Low Output configuration or vice
versa, you must power down the system.
CAUTION: AC PSU support both 220 V and 110 V input
voltages with the exception of Titanium PSU, which support
only 220 V. When two identical PSU receive different input
voltages, they can output different wattages, and trigger a
mismatch.
CAUTION: If two PSU are used, they must be of the same
type and have the same maximum output power.