EasyManua.ls Logo

Dell poweredge VRTX - Cpu0003; Cpu0004

Dell poweredge VRTX
931 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0003
Message CPU
arg1
is stuck in POST.
Arguments
•
arg1 =
number
Detailed
Description
None
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Reduce system configuration to minimum memory and remove all PCI devices. If
system completes POST, update system BIOS. Re-install memory and PCI one component at a
time to meet the original configuration. 3) If the issue still persists, contact technical support.
Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0004
Message CPU
arg1
failed to initialize.
Arguments
•
arg1 =
number
Detailed
Description
None
141