EasyManua.ls Logo

Dell poweredge VRTX - Pwr8507; Pwr8508

Dell poweredge VRTX
931 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8507
Message System Input Power Cap changed from
arg1
W AC to
arg2
W AC.
Arguments
•
arg1 =
previous power value
•
arg2 =
new power value
Detailed
Description
The system Input Power Cap was changed from the value to the value indicated in the
message.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8508
Message New power budget (
arg1
W AC) may permit future degradation of redundancy.
Arguments
•
arg1 =
power value
Detailed
Description
If the power budget exceeds the effective capacity for the current redundancy policy, it is
possible for power allocations to grow beyond the effective capacity, which would reduce
redundancy capabilities.