EasyManua.ls Logo

Dell poweredge VRTX - Enc13; Enc14

Dell poweredge VRTX
931 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trap/EventID 4339
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
ENC13
Message Unsupported configuration detected on
arg1
.
arg2arg3
Arguments
•
arg1 =
Enclosure Name
•
arg2 =
EMM0 1
•
arg3 =
EMM1 2
Detailed
Description
An unsupported configuration was detected. The SCSI rate of the Enclosure Management
Modules (EMMs) are not the same.
Recommended
Response Action
Replace one of the EMMs with the matching SCSI rate EMM.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
Trap/EventID 4338
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
ENC14
Message The number of enclosures connected on
arg1
has exceeded the maximum limit supported by the
controller.
Arguments
•
arg1 =
controller name
Detailed
Description
There are too many enclosures attached to the controller port. When the enclosure limit is
exceeded, the controller loses contact with all enclosures attached to the port. This is an
unsupported configuration.
218

Table of Contents

Other manuals for Dell poweredge VRTX

Related product manuals