EasyManua.ls Logo

Dell poweredge VRTX - Pci3010; Pci3011

Dell poweredge VRTX
931 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI3010
Message A non-fatal IO error detected on a component at bus
arg1
device
arg2
function
arg3
.
Arguments
•
arg1 =
bus
•
arg2 =
device
•
arg3 =
func
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Cycle input power, update component drivers, remove and re-install the device at the next
service window.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI3011
Message The component at bus
arg1
device
arg2
function
arg3
recovered from a non-fatal IO error.
Arguments
•
arg1 =
bus
•
arg2 =
device
•
arg3 =
func
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
422