EasyManua.ls Logo

Dell poweredge VRTX - Iov108; Iov010

Dell poweredge VRTX
931 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IOV108
Message Power fault detected on PCIE device
arg1
in
arg2arg3
.
Arguments
•
arg1 =
device name
•
arg2 =
slot type
•
arg3 =
slot number
Detailed
Description
The Chassis manager detected a power fault in an adapter after the adapter was powered on.
A power fauilt may be caused a damaged adapter or an adapter whose power requirements
exceed the maximum power limits of the slot.
Recommended
Response Action
Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For
a list of supported devices, contact the service provider.
Category System Health
SubCategory IOV = IO Virtualization
Severity Severity 2 (Warning)
Trap/EventID 2554
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LCD;#LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
IOV010
Message A license is required to assign more than 2 PCIE slots to a server.
Detailed
Description
Non-licensed systems are only allowed two slots per server.
Recommended
Response Action
Import license which allows assignments of more than 2 PCIE slot per server.
Category Configuration
SubCategory IOV = IO Virtualization
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
300