SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RDU8514
Message CMC
arg1
: cannot failover, firmware update is in progress.
Arguments
•
arg1 =
slot number
Detailed
Description
A failover operation has been requested, but a failover operation cannot be completed while
CMC firmware update is in progress.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RDU8515
Message CMC
arg1
: failover was initiated by internal health monitoring process.
Arguments
•
arg1 =
slot number
Detailed
Description
A CMC failover was initiated by the CMC health monitoring process. There should be a reason
listed in the chassis log.
Recommended
Response Action
No response action is required.