13 Power on Settings
When shipped, the PSC-488 module and the PSC-232 module are set to the configuration listed in table.
All configurable parameters can be changed and stored by the user.
Function Command Value
Voltage range
SOurce:VOltage:MAximum
5
Current range
SOurce:CUrrent:MAximum
5
Text field #2 in IDN string
TYpe
“EXT” | “INT” | “P146” | “P148”
Text field #4 in IDN string
CUstom
“Not Calibrate”
Password
PAssword
“Default”
Remote shut down 0
Remote 1
At power-on the Service Request Enable Register and the Standard Event Status Enable Register are
cleared.
page 15 MANUAL May 2008
DELTA ELEKTRONIKA BV PSC SERIES