Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-110
ID
Display on LCD Keypad
Fault Name
Fault Descriptions
183
Interpolation command
failure
(IPCM)
Used for IP mode, the IP command loses synchronism
Action and Reset
Action condition
The 60C1 position command does not update
and activates normally for more
than one synchronizing cycle
Action time
Act immediately
Fault treatment parameter
N/A
Reset method
Manual reset
Reset condition
Reset immediately
Record
Yes
Cause
Corrective Actions
The 60C1 position command does
not update and activates normally
for more than one synchronizing
cycle
Verify if the operation time of
upper control program is too long. You can prolong
the synchronizing cycle.