Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-112
ID
Display on LCD Keypad
Fault Name
Fault Descriptions
185
Motor code error
(MoTo)
1. The detected motor code does not match the drive
2. Cannot find the motor code
Action and Reset
Action condition
Activates when the drive does not have the motor code
Action time
Act immediately
Fault treatment parameter
N/A
Reset method
Manual reset
Reset condition
Enter the correct motor code and Reset immediately
Record
Yes
Cause
Corrective Actions
Incorrect configuration between
the motor and the drive
Choose the correct matching model
The drive does not have the motor
code
Enter the correct motor code