EasyManua.ls Logo

Delta C2000 Plus Series - Page 151

Delta C2000 Plus Series
1259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Optional AccessoriesC2000 Plus
7-42
AC Output Reactor
When using drives in long wiring output application, ground fault (GFF), over-current (OC) and motor
over-voltage (OV) often occur. GFF and OC cause errors due to the drive’s self-protective mechanism;
over-voltage damages motor insulation.
The excessive length of the output wires makes the grounded stray capacitance too large, increase
the three-phase output common mode current, and the reflected wave of the long wires makes the motor
dv / dt and the motor terminal voltage too high. Thus, installing a reactor on the drive’s output side can
increase the high-frequency impedance to reduce the dv / dt and terminal voltage to protect the motor.
Installation
Installing an AC output reactor in series between the three output phases U V W and the motor, as
shown in the figure below:
Figure 7-25 Wiring of AC output reactor
Applicable Reactors:
200V–230V, 50/60 Hz / Heavy Duty
Model HP
Rated
current
(Arms)
Saturation
current
(Arms)
3%
impedance
(mH)
5%
impedance
(mH)
Built-in
DC
reactor
Output AC
reactor Delta
part #
Weight
(kg)
Heat
Dissipation
(W)
VFD007C23A-21 1 5 9 2.536 4.227 No DR005L0254 1.5 15
VFD015C23A-21 2 8 14.4 1.585 2.642 No DR008L0159 2.5 30
VFD022C23A-21 3 11 19.8 1.152 1.922 No DR011L0115 3.0 33
VFD037C23A-21 5 17 30.6 0.746 1.243 No DR017LP746 3.6 34
VFD055C23A-21 7.5 25 45 0.507 0.845 No DR025LP507 5.5 50
VFD075C23A-21 10 33 59.4 0.32 0.534 No DR033LP320 6.5 50
VFD110C23A-21 15 49 88.2 0.216 0.359 No DR049LP215 8.6 62
VFD150C23A-21 20 65 117 0.163 0.271 No DR065LP162 12 70
VFD185C23A-21 25 75 135 0.169 0.282 No DR075LP170 14.5 80
VFD220C23A-21 30 90 162 0.141 0.235 No DR090LP141 15 80
VFD300C23A-00
VFD300C23A-21
40 120 216 0.106 0.176 Yes DR146LP087 22 110
VFD370C23A-00
VFD370C23A-21
50 146 262.8 0.087 0.145 Yes DR146LP087 22 110