Chapter 12 Descriptions of Parameter SettingsC2000 Plus
12.1-01-7
00-05
Coefficient Gain in Actual Output Frequency
Default: 1.00
Settings 0.00–160.00
Sets the user-defined unit coefficient gain. Set Pr.00-04 = 31 to display the calculation result on
the screen (calculation = output frequency × Pr.00-05).
00-06
Firmware Version
Default: Read only
Settings Read only
00-07
Parameter Protection Password Input
Default: 0
Settings 0–65535
0–4: the number of password attempts allowed
This parameter allows you to enter your password (which is set in Pr.00-08) to unlock the
parameter protection and to make changes to the parameter.
To avoid problems in the future, be sure to write down the password after you set this parameter.
Pr.00-07 and Pr.00-08 are used to prevent personnel from setting other parameters by accident.
If you forget the password, clear the password setting by input 9999 and press the ENTER key,
then enter 9999 again and press ENTER within 10 seconds. After decoding, all the settings return
to default.
When setting is under password protection, all the parameters read 0, except Pr.00-08.
00-08
Parameter Protection Password Setting
Default: 0
Settings 0–65535
0: No password protection or password entered correctly (Pr.00-07)
1: Parameter has been set
This parameter is for setting the password protection. Password can be set directly the first time.
After you set the password, the value of Pr.00-08 is 1, which means password protection is
activated. At this time, if you want to change any of the parameter settings, you must enter the
correct password in Pr.00-07 to deactivate the password temporarily, and this would make Pr.00-
08 become 0. After you finish setting the parameters, reboot the motor drive and the password is
activated again.
Entering the correct password in Pr.00-07 only temporarily deactivates the password. To
permanently deactivate password protection, set Pr.00-08 to 0 manually. Otherwise, password
protection is always reactivated after you reboot the motor drive.
The keypad copy function works normally only when the password protection is deactivated
(temporarily or permanently), and password set in Pr.00-08 cannot be copied to the keypad. So
when copying parameters from the keypad to the motor drive, set the password manually again
in the motor drive to activate password protection.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
AltitudeUp to 1000m without derating
CommunicationCANopen
Output Current2.5A
Protection FeaturesOvercurrent, Overvoltage, Overtemperature
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity95% RH (non-condensing)