Chapter 13 Warning CodesC2000 Plus
13-9
ID No. Display on LCD Keypad Warning Name Description
8
Save error 2
(SE2)
Keypad COPY error 2: parameter writing error
Action and Reset
Action condition
SE2warning
occurs when writing the parameters incorrectly at the time you
copy parameters to the drive. For example, you copy the new firmware version
with added parameters to the drive with old firmware version.
Action time N/A
Warning setting parameter N/A
Reset method Manual reset
Reset condition Immediately reset
Record N/A
Cause Corrective Actions
Add new parameters to the new
firmware version.
SE2: In this stage, the copied data has been transmitted to the Slave.
The Slave compares and processes the copied data, and then saves the data
to
the Data ROM.
During the process, the data error (should be attribution error)
may occur, or the
data cannot be saved to EEPROM. At this time, the warning
occurs.
It is suggested to
check the status of Data ROM and remove the error causes
first.
If you cannot clear the error, please contact Delta.
Malfunction caused by
interference
Verify the wiring and grounding of the main cir
cuit, control circuit and the encoder
for effective anti-interference performance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
AltitudeUp to 1000m without derating
CommunicationCANopen
Output Current2.5A
Protection FeaturesOvercurrent, Overvoltage, Overtemperature
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity95% RH (non-condensing)