Chapter 13 Warning CodesC2000 Plus
13-90
ID No. Display on LCD Keypad Warning Name Description
123
Deceleration energy
backup (dEb)
Deceleration energy backup
Action and Reset
Action condition Software detection
Action time N/A
Warning setting parameter
0: Disable
1: dEb with auto accel./decel., the output
frequency will note return after power
reply.
2: dEb with auto accel./decel., the output frequency will return after power reply.
3: dEb low-voltage control, then increase to 350V
DC
/700V
DC
and decelerate to
stop.
4: dEb high-voltage control of 350V
DC
/700V
DC
and decelerate to stop
Reset method Manual reset
Reset condition Immediately resets
Record N/A
Cause Corrective Actions
Instantaneous power off or low
voltage and unstable/ sudden
heavy load of the power that
cause the voltage drop
Check the power consumption
Unexpected power off Check the power consumption

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
AltitudeUp to 1000m without derating
CommunicationCANopen
Output Current2.5A
Protection FeaturesOvercurrent, Overvoltage, Overtemperature
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity95% RH (non-condensing)

Related product manuals