Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-54
ID* Display on LCD Keypad Fault Name Fault Descriptions
51
External base block
(bb)
When the contact of MIx = bb
is ON, the output stops
immediately and displays bb on the keypad.
The motor
is in free running.
Action and Reset
Action condition MIx = bb and the MI terminal is ON
Action time Act immediately
Fault treatment parameter N/A
Reset method The display bbis automatically cleared after the fault is cleared.
Reset condition N/A
Record No
Cause Corrective Actions
When Mix = bb activates
Verify if the system is back to normal condition, and then press RESET
key to
go back to the default.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
AltitudeUp to 1000m without derating
CommunicationCANopen
Output Current2.5A
Protection FeaturesOvercurrent, Overvoltage, Overtemperature
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity95% RH (non-condensing)