Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-56
ID* Display on LCD Keypad Fault Name Fault Descriptions
53
SW Code Error
(ccod)
This fault code occurs when the
firmware version and
the control board ID# dont match.
Action and Reset
Action condition N/A
Action time N/A
Fault treatment parameter N/A
Reset method N/A
Reset condition N/A
Record N/A
Cause Corrective Actions
The firmware version may be
wrong. For example: Firmware of
C2000 series is burned into control
board of CH2000 series.
Return to the factory for repair.