Chapter 12 Description of Parameter SettingsCP2000
12.1-06-25
Low Current Action
Default: 0
Settings 0: No function
1: Fault and coast to stop
2: Fault and ramp to stop by the 2
nd
deceleration time
3: Warn and operation continue
The drive operates according to the setting for Pr.06-73 when the output current is lower than
the setting for Pr.06-71, and when the time of the low current exceeds the detection time for
Pr.06-72. Use this parameter with the external multi-function output terminal 44 (for low current
output).
The low current detection function does not execute when the drive is in sleep or standby status.
Sets Pr.06-71 low current level according to the drive’s rated current, the equation is Pr.00-01
(drive’s rated current) x Pr.06-71 (low current setting level)% = low current detection level (A).
The drive changes the setting for Pr.00-01 (rated current) according to the setting for Pr.00-16
(load selection).
dEb Motion Offset
Default:
20.0/ 40.0/ 50.0/ 60.0
Settings 230V series: 0.0–200.0 V
DC
460V series: 0.0–200.0 V
DC
575V series: 0.0–200.0 V
DC
690V series: 0.0–200.0 V
DC
Fire Mode
Default: 0.00
Settings 0: Disable
1: Operates in counter clockwise direction
2: Operates in clockwise direction
This parameter works with multi-input function terminal 58 or 59 and multi-output function
terminal 53 and 54.
0: Fire mode is disabled.
1: When there is a fire, the motor operates in counter clockwise direction (U, V, W).
2: When there is a fire, the motor operates in clockwise direction (U, W, V).
Operating Frequency when Running Fire Mode
Default: 60.00
Settings 0.00–599.00 Hz
Sets the drive’s frequency when the fire mode is enabled.

Table of Contents

Other manuals for Delta CP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta CP2000 Series and is the answer not in the manual?

Delta CP2000 Series Specifications

General IconGeneral
Output Voltage0 ~ Input Voltage
Communication InterfaceRS-485
Storage Temperature-20°C to 60°C
Input Voltage200-240V AC, 380-480V AC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit

Related product manuals