8 Settings
Installation and Operation Manual for Inverter RPI M50A_12s V1 EU EN 2017-03-09
104
8.4.11 Max. power (maximum active power)
These parameters are set according to the
requirements of the selected country. Changing
these parameter settings can invalidate the type
approval of the unit. Change this setting only after
consultation with Delta customer service.
Overview
This function allows you to set the maximum active power fed
into the grid.
Setting options
Parameter Description Setting range
Max. Power
Limits the maximum power that can be fed into the grid.
0 .. 55000 W
Menu item path
Main Menu > Install Settings > Max. Power
Setting the maximum active power
E-Today: 0kWh
Power: 0W
Status: On Grid
10.Sep 2014 15:32
1. If the default information is displayed, press any button to open the main menu.
Otherwise, press the
EXIT
button repeatedly until the main menu is displayed.
Inverter Info.
General Settings
Install Settings
2. Use the and buttons to select the Install Settings entry and then press the
ENT
button.
Password 0 * * *
energy production.
Adj. would affect
Warning:
3. This function is protected with password 5555.
Use the
and buttons to set the individual numerals.
Press the
ENT
button to confirm a number.
AC Connection: 3P3W
EPO: Normal Close
Anti-islanding: ON
Max. Power: 100%
Return to Factory
4. Use the buttons and to select the entry Max. Power and press the
ENT
button.
→ The shape of the arrow changes
, the value can be changed.
The currently set value is displayed after the entry.
5. Use the and buttons to configure the value and then press the
ENT
button.