Chapter 5 Parameters|VFD-B-P Series
Revision April 2009, SW V1.00 5-27
00 - 09 Control method
Factory Setting: 00
Settings 00 V/f control
01 V/f + PG Control
02 Vector Control
03 Vector + PG Control
This parameter determines the control method of the AC motor drive.
PG is encoder (Pulse Generator) feedback for which an option PG card is required.
Setting 00 and 01 are for V/f control mode. Setting 02 and 03 are for vector control mode.
When the control model is changed, the settings of Pr.02-03(PWM Carrier Frequency
Selections), Pr.06-01(Over-Current Stall Prevention during Accel), Pr.06-02(Over-Current Stall
Prevention during Operation), Pr.06-04(Over-Torque Detection Level) and Pr.08-07(Current
Limit for Speed Search) will be reset to the factory setting of the setting model.
00 - 10 Reserved

Other manuals for Delta VFD-B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-B Series and is the answer not in the manual?

Delta VFD-B Series Specifications

General IconGeneral
SeriesVFD-B
Cooling MethodFan cooling
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Control ModeV/F control, Sensorless Vector Control
CommunicationRS-485
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overload, Overtemperature, Short Circuit
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity90% RH (non-condensing)
Altitude1000m (Derating required above 1000m)