Details of Error code Display Coping strategies
11
Main CPU failed to receive rm-
ware for rewriting sent from
CX870 (when an error occurred).
U p d a t i n g f a i l 1 1
Turn on the power again. Update will
start automatically.
12
Firmware for rewriting sent from
CX870 received by the Main CPU
contained corrupt data (Check
Sum error occurred).
U p d a t i n g f a i l 1 2
Turn on the power again. Update will
start automatically.
13
The erasing of block data failed
before Main CPU was rewritten.
E r a s e f a i l 1 3
Turn on the power again. Update will
start automatically.
14
The rewriting of block data failed
when Main CPU was rewritten.
U p d a t i n g f a i l 1 4
Turn on the power again. Update will
start automatically.
15
Data was found to be corrupt dur-
ing verication after the Main CPU
was rewritten.
U p d a t e C h e c k N G 1 5
Turn on the power again. Update will
start automatically.
20
Failed to acquire the IP address
before CX870 rewrite (Boot
Loader Mode). (Auto IP)
C o n n e c t i o n F a i l 2 0
Check the network connection. Update
in an environment where there is a
small network load.
21
Failed to acquire the IP address
before CX870 rewrite (Boot
Loader Mode). (when timed out)
C o n n e c t i o n F a i l 2 1
Check the network connection. Update
in an environment where there is a
small network load.
22 Failed to log in to DPMS.
L o g i n f a i l e d 2 2
Initialize the unit and try updating
again.
Update in an environment where there
is a small network load.
23
Line etc. is congested when log-
ging in to DPMS.
S e r v e r i s b u s y 2 3
Update in an environment where there
is a small network load.
24 Connection to DPMS failed.
C o n n e c t i o n F a i l 2 4
Check the network connection. Update
in an environment where there is a
small network load.
25 Failed to change the CX870 mode.
C o n n e c t i o n F a i l 2 5
Initialize the unit and try updating
again.
26
Timeout occurred obtaining data
when downloading the Main CPU
rmware.Received an invalid pa-
cage version. Received an invalid
pacage version.
D o w n l o a d f a i l 2 6
Check the network connection. Update
in an environment where there is a
small network load.
27 Failed to change the CX870 mode.
D o w n l o a d f a i l 2 7
Initialize the unit and try updating
again.
36
Log in to DPMS failed when re-
writing the Main CPU.
L o g i n f a i l e d 3 6
Update in an environment where there
is a small network load.
37
Unit logs in to DPMS but the line
etc. is congested when rewriting
the Main CPU.
S e r v e r i s b u s y 3 7
Update in an environment where there
is a small network load.
38
Connect to DPMS failed when
rewriting the Main CPU.
C o n n e c t i o n F a i l 3 8
Check the network connection. Update
in an environment where there is a
small network load.
65

Table of Contents

Other manuals for Denon AVR-S700W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Denon AVR-S700W and is the answer not in the manual?

Denon AVR-S700W Specifications

General IconGeneral
Channels7.2
Power Output per Channel75 W (8 ohms, 20 Hz - 20 kHz, 0.08% THD)
Frequency Response10 Hz - 100 kHz
Total Harmonic Distortion0.08%
Signal-To-Noise Ratio98 dB
Input Impedance47 kOhms
Input Sensitivity200 mV
HDMI Inputs6
HDMI Outputs1
Composite Inputs2
Component Inputs2
Analog Inputs4
Composite Output1
Component Output1
Wi-FiYes
BluetoothYes
AirPlayYes
DLNAYes
HDMI Pass-ThroughYes
HDMI SwitchingYes
3D TechnologyYes
Digital Inputs2 Optical
Supported Audio FormatsDTS-HD Master Audio, Dolby TrueHD
Supported Video Formats4K, 3D
Additional FeaturesAudyssey MultEQ
Tuner Presets56
Dimensions17.1 x 13.3 x 6.6 inches